{"id":11684,"date":"2021-01-01T17:36:01","date_gmt":"2021-01-01T17:36:01","guid":{"rendered":"http:\/\/lequia-udg.com\/2021\/01\/01\/scaling-up-and-long-term-operation-of-a-full-scale-two-stage-partial-nitritation-anammox-system-treating-landfill-leachate\/"},"modified":"2024-04-18T16:03:10","modified_gmt":"2024-04-18T16:03:10","slug":"scaling-up-and-long-term-operation-of-a-full-scale-two-stage-partial-nitritation-anammox-system-treating-landfill-leachate","status":"publish","type":"post","link":"https:\/\/lequia-udg.com\/ca\/2021\/01\/01\/scaling-up-and-long-term-operation-of-a-full-scale-two-stage-partial-nitritation-anammox-system-treating-landfill-leachate\/","title":{"rendered":"Scaling-up and long-term operation of a full-scale two-stage partial nitritation-anammox system treating landfill leachate"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"11684\" class=\"elementor elementor-11684 elementor-6744\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2f916660 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2f916660\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6904c54c ts-bg-color-over-image\" data-id=\"6904c54c\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-41ee51f9 ts-align-left elementor-widget elementor-widget-ts_heading\" data-id=\"41ee51f9\" data-element_type=\"widget\" data-widget_type=\"ts_heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t<div class=\"ts-heading-subheading ts-reverse-heading-yes animation-style4\"><h4 class=\"ts-custom-heading ts-custom-subtitle\">\r\n\t\t\t\r\n\t\t\t\tAuthors: Magr\u00ed A., Ruscalleda M., Vil\u00e0 A., Akaboci T.R.V., Dolors Balaguer M., Llenas J.M., Colprim J.                                                                                                         \r\n\t\t\t\r\n\t\t\t<\/h4>\r\n\t\t<h2 class=\"ts-custom-heading ts-custom-heading-title\">\r\n\t\t\t\r\n\t\t\t\tScaling-up and long-term operation of a full-scale two-stage partial nitritation-anammox system treating landfill leachate\r\n\t\t\t\r\n\t\t\t<\/h2>\r\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-17563f56 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"17563f56\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3d62c30b ts-bg-color-over-image\" data-id=\"3d62c30b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-62973fe8 elementor-widget-tablet__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"62973fe8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>(1) Background: Biological treatment of leachate in landfill sites using anaerobic ammonium oxidation (anammox) is challenging because of the intrinsic characteristics of this complex wastewater. In this work, the scale-up and subsequent full-scale implementation of the PANAMMOX<sup>\u00ae<\/sup>\u00a0technology (LEQUIA Research Group, Girona, Catalonia, Spain) are presented as a case study to achieve long-term nitrogen (N) removal from mature leachate mostly through a completely autotrophic pathway. (2) Methods: The treatment system consists of two sequencing batch reactors (SBRs) running in series to individually operate partial nitritation (PN) and anammox (A). Following biological treatment, physicochemical oxidation (i.e., Fenton-based process) was used to remove the remaining non-biodegradable organic matter. A cost analysis comparative was conducted in relation to the former technology used on-site for treating the leachate. (3) Results: The scale-up of the process from pilot- to full-scale was successfully achieved, finally reaching an average removal of 7.4 kg N\/d. The composition of the leachate changed over time, but especially once the landfill site stopped receiving solid waste (this fact involved a marked increase in the strength of the leachate). The adjustment of the alkalinity-to-ammonium ratio before feeding PN-SBR helped to improve the N-removal efficiency. Values of conductivity above 25 mS\/cm in A-SBR could negatively affect the performance of the anammox process, making it necessary to consider a dilution strategy according to the on-line monitoring of this parameter. The analysis of the operational costs showed that by implementing the PANAMMOX<sup>\u00ae<\/sup>\u00a0technology (LEQUIA Research Group, Girona, Catalonia, Spain) in the landfill site, savings up to 32% were achievable. (4) Conclusions: Treatment of mature landfill leachate in such a two-stage PN-A system was demonstrated as feasible and economically appealing despite the complexity of this industrial wastewater. Accurate expert supervision of the process was a key factor to reaching good performances.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5a56d7b6 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5a56d7b6\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3ddd2848 ts-bg-color-over-image\" data-id=\"3ddd2848\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6e938ad8 elementor-widget elementor-widget-accordion\" data-id=\"6e938ad8\" data-element_type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1851\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1851\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Informaci\u00f3 addicional<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1851\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1851\"><table style=\"border: hidden;\">\n<tbody>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Year:<\/strong><\/td>\n<td>2021<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Authors:<\/strong><\/td>\n<td>Magr\u00ed A., Ruscalleda M., Vil\u00e0 A., Akaboci T.R.V., Dolors Balaguer M., Llenas J.M., Colprim J.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Reference:<\/strong><\/td>\n<td>\n<p>Processes, Open Access, Volume 9, Issue 52021, Article number 800<\/p>\n<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Link:<\/strong><\/td>\n<td><a href=\"http:\/\/dx.doi.org\/10.3390\/pr9050800\" target=\"_blank\" rel=\"noopener\">http:\/\/dx.doi.org\/10.3390\/pr9050800<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f9d4d elementor-widget elementor-widget-spacer\" data-id=\"7f9d4d\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Authors: Magr\u00ed A., Ruscalleda M., Vil\u00e0 A., Akaboci T.R.V., Dolors Balaguer M., Llenas J.M., Colprim J. Scaling-up and long-term operation of a full-scale two-stage partial nitritation-anammox system treating landfill leachate (1) Background: Biological treatment of leachate in landfill sites using anaerobic ammonium oxidation (anammox) is challenging because of the intrinsic characteristics of this complex wastewater. &hellip; <a href=\"https:\/\/lequia-udg.com\/ca\/2021\/01\/01\/scaling-up-and-long-term-operation-of-a-full-scale-two-stage-partial-nitritation-anammox-system-treating-landfill-leachate\/\" class=\"more-link\" title=\"Continue reading <span class=\"screen-reader-text\">Scaling-up and long-term operation of a full-scale two-stage partial nitritation-anammox system treating landfill leachate<\/span>&#8220;>Continue reading <span class=\"screen-reader-text\">Scaling-up and long-term operation of a full-scale two-stage partial nitritation-anammox system treating landfill leachate<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[64],"tags":[],"class_list":["post-11684","post","type-post","status-publish","format-standard","hentry","category-articles-ca"],"_links":{"self":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/comments?post=11684"}],"version-history":[{"count":1,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11684\/revisions"}],"predecessor-version":[{"id":11685,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11684\/revisions\/11685"}],"wp:attachment":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/media?parent=11684"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/categories?post=11684"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/tags?post=11684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}