{"id":11812,"date":"2019-01-01T16:48:03","date_gmt":"2019-01-01T16:48:03","guid":{"rendered":"http:\/\/lequia-udg.com\/2019\/01\/01\/simulation-tests-of-in-situ-groundwater-denitrification-with-aquifer-buried-biocathodes\/"},"modified":"2024-04-18T16:27:59","modified_gmt":"2024-04-18T16:27:59","slug":"simulation-tests-of-in-situ-groundwater-denitrification-with-aquifer-buried-biocathodes","status":"publish","type":"post","link":"https:\/\/lequia-udg.com\/ca\/2019\/01\/01\/simulation-tests-of-in-situ-groundwater-denitrification-with-aquifer-buried-biocathodes\/","title":{"rendered":"Simulation tests of in situ groundwater denitrification with aquifer-buried biocathodes"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"11812\" class=\"elementor elementor-11812 elementor-6399\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8087740 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8087740\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-30259c89 ts-bg-color-over-image\" data-id=\"30259c89\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-249ef9a2 ts-align-left elementor-widget elementor-widget-ts_heading\" data-id=\"249ef9a2\" data-element_type=\"widget\" data-widget_type=\"ts_heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t<div class=\"ts-heading-subheading ts-reverse-heading-yes animation-style4\"><h4 class=\"ts-custom-heading ts-custom-subtitle\">\r\n\t\t\t\r\n\t\t\t\tAuthors: Cecconet, D., Bolognesi, S., Callegari, A., Capodaglio, A.G.                                                                                                         \r\n\t\t\t\r\n\t\t\t<\/h4>\r\n\t\t<h2 class=\"ts-custom-heading ts-custom-heading-title\">\r\n\t\t\t\r\n\t\t\t\tSimulation tests of in situ groundwater denitrification with aquifer-buried biocathodes\r\n\t\t\t\r\n\t\t\t<\/h2>\r\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-31f85a42 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"31f85a42\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-13dbf174 ts-bg-color-over-image\" data-id=\"13dbf174\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-166551d8 elementor-widget-tablet__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"166551d8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bioelectrochemical systems (BES) application was proposed for a variety of specific uses, due to these systems\u2019 characteristics: electrodes can act as virtually inexhaustible electron acceptors\/donors, offering a growth-support surface for microorganisms, and stimulating naturally-occurring microbial degradation activities. In situ, groundwater denitrification therefore seems to be a potential candidate for their use. In this study, buried biocathodes were operated in laboratory settings for the simulation of in situ groundwater denitrification. Two alternative configurations were tested: biocathode buried in sand, and biocathode buried in gravel. A control test with a biocathode in absence of sand\/gravel was also performed. In all the cases, biocathodes were driven by power supply or potentiostat to guarantee a steady electron flux to the cathode. The presence of sand and gravel strongly influenced the denitrification process: in both configurations, accumulation of intermediate N-forms was detected, suggesting that the denitrification process was only partially achieved. In addition, a significant decrease (in the 20\u201336% range) in nitrate removal rates was measured in sand and gravel setups compared to the control reactor; this issue could be attributed to lack of recirculation that limited contact between substrate and electrode-adherent biofilm. Biocathodes buried in gravel obtained better results than those buried in sand due to the lower packing of the medium. The results of this study suggest that, in order to achieve successful in situ treatment, special design of submerged-biocathodic BESs is necessary.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-230412f ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"230412f\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-42ad0e61 ts-bg-color-over-image\" data-id=\"42ad0e61\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-34946c14 elementor-widget elementor-widget-accordion\" data-id=\"34946c14\" data-element_type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-8821\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-8821\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Informaci\u00f3 addicional<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-8821\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-8821\"><table style=\"border: hidden;\">\n<tbody>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Year:<\/strong><\/td>\n<td>2019<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Authors:<\/strong><\/td>\n<td>Cecconet, D., Bolognesi, S., Callegari, A., Capodaglio, A.G.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Reference:<\/strong><\/td>\n<td>HeliyonOpen Access Volume 5, Issue 7, July 2019, Article number e02117<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Link:<\/strong><\/td>\n<td><a href=\"http:\/\/dx.doi.org\/10.1016\/j.heliyon.2019.e02117\" target=\"_blank\" rel=\"noopener\">http:\/\/dx.doi.org\/10.1016\/j.heliyon.2019.e02117<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e644372 elementor-widget elementor-widget-spacer\" data-id=\"6e644372\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Authors: Cecconet, D., Bolognesi, S., Callegari, A., Capodaglio, A.G. Simulation tests of in situ groundwater denitrification with aquifer-buried biocathodes Bioelectrochemical systems (BES) application was proposed for a variety of specific uses, due to these systems\u2019 characteristics: electrodes can act as virtually inexhaustible electron acceptors\/donors, offering a growth-support surface for microorganisms, and stimulating naturally-occurring microbial degradation &hellip; <a href=\"https:\/\/lequia-udg.com\/ca\/2019\/01\/01\/simulation-tests-of-in-situ-groundwater-denitrification-with-aquifer-buried-biocathodes\/\" class=\"more-link\" title=\"Continue reading <span class=\"screen-reader-text\">Simulation tests of in situ groundwater denitrification with aquifer-buried biocathodes<\/span>&#8220;>Continue reading <span class=\"screen-reader-text\">Simulation tests of in situ groundwater denitrification with aquifer-buried biocathodes<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[64],"tags":[],"class_list":["post-11812","post","type-post","status-publish","format-standard","hentry","category-articles-ca"],"_links":{"self":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/comments?post=11812"}],"version-history":[{"count":1,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11812\/revisions"}],"predecessor-version":[{"id":11813,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11812\/revisions\/11813"}],"wp:attachment":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/media?parent=11812"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/categories?post=11812"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/tags?post=11812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}