{"id":11887,"date":"2018-01-01T15:40:21","date_gmt":"2018-01-01T15:40:21","guid":{"rendered":"http:\/\/lequia-udg.com\/2018\/01\/01\/advanced-biological-activated-carbon-filter-for-removing-pharmaceutically-active-compounds-from-treated-wastewater\/"},"modified":"2024-04-18T17:02:33","modified_gmt":"2024-04-18T17:02:33","slug":"advanced-biological-activated-carbon-filter-for-removing-pharmaceutically-active-compounds-from-treated-wastewater","status":"publish","type":"post","link":"https:\/\/lequia-udg.com\/ca\/2018\/01\/01\/advanced-biological-activated-carbon-filter-for-removing-pharmaceutically-active-compounds-from-treated-wastewater\/","title":{"rendered":"Advanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"11887\" class=\"elementor elementor-11887 elementor-6488\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-18675ede ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"18675ede\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ad3632b ts-bg-color-over-image\" data-id=\"ad3632b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-22ac523f ts-align-left elementor-widget elementor-widget-ts_heading\" data-id=\"22ac523f\" data-element_type=\"widget\" data-widget_type=\"ts_heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t<div class=\"ts-heading-subheading ts-reverse-heading-yes animation-style4\"><h4 class=\"ts-custom-heading ts-custom-subtitle\">\r\n\t\t\t\r\n\t\t\t\tAuthors: Sbardella, L.,, Comas, J., Fenu, A., Rodriguez-Roda, I., Weemaes, M.                                                                                                         \r\n\t\t\t\r\n\t\t\t<\/h4>\r\n\t\t<h2 class=\"ts-custom-heading ts-custom-heading-title\">\r\n\t\t\t\r\n\t\t\t\tAdvanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater\r\n\t\t\t\r\n\t\t\t<\/h2>\r\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-76bd59c ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"76bd59c\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-21b5d84a ts-bg-color-over-image\" data-id=\"21b5d84a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-68791362 elementor-widget-tablet__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"68791362\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Through their release of effluents, conventional wastewater treatment plants (WWTPs) represent a major pollution point sources for pharmaceutically active compounds (PhACs) in water bodies. The combination of a biological activated carbon (BAC) filter coupled with an ultrafiltration (UF) unit was evaluated as an advanced treatment for PhACs removal at pilot scale. The BAC-UF pilot plant was monitored for one year. The biological activity of the biofilm that developed on the granular activated carbon (GAC) particles and the contribution of this biofilm to the overall removal of PhACs were evaluated. Two different phases were observed during the long-term monitoring of PhACs removal. During the first 9200 bed volumes (BV; i.e., before GAC saturation), 89, 78, 83 and 79% of beta-blockers, psychiatric drugs, antibiotics and a mix of other therapeutic groups were removed, respectively. The second phase was characterized by deterioration of the overall performances during the period between 9200 and 13,800 BV. To quantify the respective contribution of adsorption and biodegradation, a lab-scale setup was operated for four months and highlighted the essential role played by GAC in biofiltration units. Physical adsorption was indeed the main removal mechanism. Nevertheless, a significant contribution due to biological activity was detected for some PhACs. The biofilm contributed to the removal of 22, 25, 30, 32 and 35% of ciprofloxacin, bezafibrate, ofloxacin, azithromycin and sulfamethoxazole, respectively.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9c7b525 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9c7b525\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-74c84097 ts-bg-color-over-image\" data-id=\"74c84097\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-412f7e3 elementor-widget elementor-widget-accordion\" data-id=\"412f7e3\" data-element_type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-6831\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-6831\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Informaci\u00f3 addicional<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-6831\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-6831\"><table style=\"border: hidden;\">\n<tbody>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Any:<\/strong><\/td>\n<td>2018<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Autors:<\/strong><\/td>\n<td>Sbardella, L.,, Comas, J., Fenu, A., Rodriguez-Roda, I., Weemaes, M.<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Referencia:<\/strong><\/td>\n<td>Science of the Total Environment Volume 636, 15 September 2018, Pages 519-529<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Enlla\u00e7:<\/strong><\/td>\n<td><a href=\"http:\/\/dx.doi.org\/10.1016\/j.scitotenv.2018.04.214\" target=\"_blank\" rel=\"noopener\">http:\/\/dx.doi.org\/10.1016\/j.scitotenv.2018.04.214<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bf99b08 elementor-widget elementor-widget-spacer\" data-id=\"2bf99b08\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Authors: Sbardella, L.,, Comas, J., Fenu, A., Rodriguez-Roda, I., Weemaes, M. Advanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater Through their release of effluents, conventional wastewater treatment plants (WWTPs) represent a major pollution point sources for pharmaceutically active compounds (PhACs) in water bodies. The combination of a biological activated carbon &hellip; <a href=\"https:\/\/lequia-udg.com\/ca\/2018\/01\/01\/advanced-biological-activated-carbon-filter-for-removing-pharmaceutically-active-compounds-from-treated-wastewater\/\" class=\"more-link\" title=\"Continue reading <span class=\"screen-reader-text\">Advanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater<\/span>&#8220;>Continue reading <span class=\"screen-reader-text\">Advanced biological activated carbon filter for removing pharmaceutically active compounds from treated wastewater<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[64],"tags":[],"class_list":["post-11887","post","type-post","status-publish","format-standard","hentry","category-articles-ca"],"_links":{"self":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11887","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/comments?post=11887"}],"version-history":[{"count":1,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11887\/revisions"}],"predecessor-version":[{"id":11888,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/11887\/revisions\/11888"}],"wp:attachment":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/media?parent=11887"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/categories?post=11887"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/tags?post=11887"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}