{"id":14290,"date":"2024-06-19T07:45:29","date_gmt":"2024-06-19T07:45:29","guid":{"rendered":"https:\/\/lequia-udg.com\/2024\/06\/19\/coupling-hydrological-and-sanitation-datasets-to-simulate-wastewater-derived-contamination-in-european-rivers-model-development-and-calibration\/"},"modified":"2025-03-31T14:59:05","modified_gmt":"2025-03-31T14:59:05","slug":"coupling-hydrological-and-sanitation-datasets-to-simulate-wastewater-derived-contamination-in-european-rivers-model-development-and-calibration","status":"publish","type":"post","link":"https:\/\/lequia-udg.com\/ca\/2024\/06\/19\/coupling-hydrological-and-sanitation-datasets-to-simulate-wastewater-derived-contamination-in-european-rivers-model-development-and-calibration\/","title":{"rendered":"Coupling hydrological and sanitation datasets to simulate wastewater-derived contamination in European rivers: Model development and calibration"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"14290\" class=\"elementor elementor-14290 elementor-12881\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-58ecf024 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"58ecf024\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-288fd324 ts-bg-color-over-image\" data-id=\"288fd324\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7ec7690 ts-align-left elementor-widget elementor-widget-ts_heading\" data-id=\"7ec7690\" data-element_type=\"widget\" data-widget_type=\"ts_heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t<div class=\"ts-heading-subheading ts-reverse-heading-yes animation-style4\"><h4 class=\"ts-custom-heading ts-custom-subtitle\">\r\n\t\t\t\r\n\t\t\t\tAuthors:  Klink, Janick; Perell\u00f3, Laura Aixal\u00e0; Abily, Morgan; Sal\u00f3, Joan; Rodr\u00edguez-Roda, Ignasi; Marc\u00e9, Rafael; Gernjak, Wolfgang; Corominas, Llu\u00eds\n                                                                                                       \r\n\t\t\t\r\n\t\t\t<\/h4>\r\n\t\t<h2 class=\"ts-custom-heading ts-custom-heading-title\">\r\n\t\t\t\r\n\t\t\t\tCoupling hydrological and sanitation datasets to simulate wastewater-derived contamination in European rivers: Model development and calibration\r\n\t\t\t\r\n\t\t\t<\/h2>\r\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-12e9608f ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"12e9608f\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-607cd35b ts-bg-color-over-image\" data-id=\"607cd35b\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-126798db elementor-widget-tablet__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"126798db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: #2e2e2e; font-family: gulliver, georgia, 'times new roman', times, stixgeneral, 'cambria math', 'lucida sans unicode', 'microsoft sans serif', 'segoe ui symbol', 'arial unicode ms', serif; font-size: 16px;\">Wastewater treatment plant (WWTP) discharges of microcontaminants negatively impact freshwater streams, underscoring the need for accurately mapping wastewater-derived contamination in water bodies across Europe (EU). In this study, we present a fast and open-source code for a microcontaminants fate and transport (MFT) model, capable of simulating contamination at a high resolution (15 arc second scale) across the EU. The model was developed using the best publicly available hydrological (HydroSHEDS) and sanitation (UWWTD) datasets and was rigorously calibrated, with a goodness of fit of 77.5% as measured by the R<\/span><span style=\"font-size: 12px; line-height: 0; position: relative; vertical-align: baseline; top: -0.5em; margin: 0px; padding: 0px; color: #2e2e2e; font-family: gulliver, georgia, 'times new roman', times, stixgeneral, 'cambria math', 'lucida sans unicode', 'microsoft sans serif', 'segoe ui symbol', 'arial unicode ms', serif;\">2<\/span><span style=\"color: #2e2e2e; font-family: gulliver, georgia, 'times new roman', times, stixgeneral, 'cambria math', 'lucida sans unicode', 'microsoft sans serif', 'segoe ui symbol', 'arial unicode ms', serif; font-size: 16px;\">. Importantly, the model demonstrated the ability to predict wastewater-derived contamination in water bodies, making it a valuable tool for planning the upgrade of WWTPs and improving the ecological condition of freshwater streams in the EU.\u00a0<\/span><\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-67e5ef43 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"67e5ef43\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2cc97d73 ts-bg-color-over-image\" data-id=\"2cc97d73\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3545fc6 elementor-widget elementor-widget-accordion\" data-id=\"3545fc6\" data-element_type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-5581\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-5581\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Informaci\u00f3 addicional<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-5581\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-5581\"><table style=\"border: hidden;\">\n<tbody>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Any:<\/strong><\/td>\n<td>2024<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Autors:<\/strong><\/td>\n<td>Klink, Janick; Perell\u00f3, Laura Aixal\u00e0; Abily, Morgan; Sal\u00f3, Joan; Rodr\u00edguez-Roda, Ignasi; Marc\u00e9, Rafael; Gernjak, Wolfgang; Corominas, Llu\u00eds<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Refer\u00e8ncia:<\/strong><\/td>\n<td><span class=\"Typography-module__lVnit Typography-module__Nfgvc Button-module__Imdmt\">Environmental Modelling and Software, <\/span><span class=\"Typography-module__lVnit Typography-module__fRnrd Typography-module__Nfgvc\">Volume 178, <\/span><span class=\"Typography-module__lVnit Typography-module__fRnrd Typography-module__Nfgvc\">July 2024, <\/span><span class=\"Typography-module__lVnit Typography-module__fRnrd Typography-module__Nfgvc\">Article number\u00a0106049<\/span><\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Enlla\u00e7:<\/strong><\/td>\n<td><a href=\"http:\/\/dx.doi.org\/10.1016\/j.envsoft.2024.106049\" target=\"_blank\" rel=\"noopener\">http:\/\/dx.doi.org\/10.1016\/j.envsoft.2024.106049<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35b22fd9 elementor-widget elementor-widget-spacer\" data-id=\"35b22fd9\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Authors: Klink, Janick; Perell\u00f3, Laura Aixal\u00e0; Abily, Morgan; Sal\u00f3, Joan; Rodr\u00edguez-Roda, Ignasi; Marc\u00e9, Rafael; Gernjak, Wolfgang; Corominas, Llu\u00eds Coupling hydrological and sanitation datasets to simulate wastewater-derived contamination in European rivers: Model development and calibration Wastewater treatment plant (WWTP) discharges of microcontaminants negatively impact freshwater streams, underscoring the need for accurately mapping wastewater-derived contamination in water &hellip; <a href=\"https:\/\/lequia-udg.com\/ca\/2024\/06\/19\/coupling-hydrological-and-sanitation-datasets-to-simulate-wastewater-derived-contamination-in-european-rivers-model-development-and-calibration\/\" class=\"more-link\" title=\"Continue reading <span class=\"screen-reader-text\">Coupling hydrological and sanitation datasets to simulate wastewater-derived contamination in European rivers: Model development and calibration<\/span>&#8220;>Continue reading <span class=\"screen-reader-text\">Coupling hydrological and sanitation datasets to simulate wastewater-derived contamination in European rivers: Model development and calibration<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[64],"tags":[],"class_list":["post-14290","post","type-post","status-publish","format-standard","hentry","category-articles-ca"],"_links":{"self":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/comments?post=14290"}],"version-history":[{"count":1,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14290\/revisions"}],"predecessor-version":[{"id":14291,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14290\/revisions\/14291"}],"wp:attachment":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/media?parent=14290"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/categories?post=14290"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/tags?post=14290"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}