{"id":14543,"date":"2025-07-17T13:44:38","date_gmt":"2025-07-17T13:44:38","guid":{"rendered":"https:\/\/lequia-udg.com\/2025\/07\/17\/the-hidden-challenge-of-membrane-recycling-how-drying-affects-membrane-layers\/"},"modified":"2025-08-28T08:40:52","modified_gmt":"2025-08-28T08:40:52","slug":"the-hidden-challenge-of-membrane-recycling-how-drying-affects-membrane-layers","status":"publish","type":"post","link":"https:\/\/lequia-udg.com\/ca\/2025\/07\/17\/the-hidden-challenge-of-membrane-recycling-how-drying-affects-membrane-layers\/","title":{"rendered":"The hidden challenge of membrane recycling: how drying affects membrane layers?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"14543\" class=\"elementor elementor-14543 elementor-14538\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6ff74cb1 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6ff74cb1\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1d40c37f ts-bg-color-over-image\" data-id=\"1d40c37f\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7ab8cd45 ts-align-left elementor-widget elementor-widget-ts_heading\" data-id=\"7ab8cd45\" data-element_type=\"widget\" data-widget_type=\"ts_heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t<div class=\"ts-heading-subheading ts-reverse-heading-yes animation-style4\"><h4 class=\"ts-custom-heading ts-custom-subtitle\">\r\n\t\t\t\r\n\t\t\t\tAuthors: Bianca Zappulla-Sabio, Pierre Le-Clech, Ludovic F. Dum\u00e9e, Hari Kalathil Balakrishnan, H\u00e8ctor Moncl\u00fas, Ga\u00ebtan Blandin                                                                                                        \r\n\t\t\t\r\n\t\t\t<\/h4>\r\n\t\t<h2 class=\"ts-custom-heading ts-custom-heading-title\">\r\n\t\t\t\r\n\t\t\t\tThe hidden challenge of membrane recycling: how drying affects membrane layers?\r\n\t\t\t\r\n\t\t\t<\/h2>\r\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2db437f ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2db437f\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6814bd5a ts-bg-color-over-image\" data-id=\"6814bd5a\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4559af08 elementor-widget-tablet__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"4559af08\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Improper management or storage after discharge of thin film composite membranes are challenging due to potential drying, which may affect the integrity of the material, decrease the performance and impede their potential recycling for second-hand applications. The impact of drying onto the different layers of thin film composite membranes remain empirical and poorly studied. This work systematically assessed the impact of the drying phenomena on the physical changes across poly(amide) and poly(sulfone) layers by applying drying\/rewetting protocols consisting of (1) soaking the membrane in a solvent, (2) drying at 60\u00a0\u00b0C and (3) rewetting with ethanol. After each step, membrane performance as well as surface characterization were assessed. Severe loss of permeabilities, up to 65 and 90\u00a0% for the poly(amide) and the poly(sulfone) layer respectively, were observed. Drying effect was demonstrated to be quickly reversible (1\u00a0min soaking in ethanol) for the poly(amide) layer even over several drying-rehydration cycles. Permeability of the poly(sulfone) layer appeared to be permanently impacted due to a possible irreversible surface shrinkage and pores collapsing showing permanent changes in the poly(sulfone) layer. These findings highlight the importance of studying membrane drying to prevent further performance loss, optimize material lifetime, ensure continuity of operation, and enable membrane recycling.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3dc032c3 ts-col-stretched-none ts-bg-color-over-image elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3dc032c3\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7c4b446e ts-bg-color-over-image\" data-id=\"7c4b446e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6e87598f elementor-widget elementor-widget-accordion\" data-id=\"6e87598f\" data-element_type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1851\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1851\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Informaci\u00f3 addicional<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1851\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1851\"><table style=\"border: hidden;\">\n<tbody>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Year:<\/strong><\/td>\n<td>2025<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Authors:<\/strong><\/td>\n<td>Bianca Zappulla-Sabio, Pierre Le-Clech, Ludovic F. Dum\u00e9e, Hari Kalathil Balakrishnan, H\u00e8ctor Moncl\u00fas, Ga\u00ebtan Blandin<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Reference:<\/strong><\/td>\n<td>\n<div class=\"text-xs\">Journal of water process engineering , 2025, Vol.76<\/div>\n<\/td>\n<\/tr>\n<tr style=\"border-bottom: 1px solid #efefef;\">\n<td align=\"right\" width=\"200\"><strong>Link:<\/strong><\/td>\n<td><a href=\"https:\/\/doi.org\/10.1016\/j.jwpe.2025.108110\" target=\"_blank\" rel=\"noopener\">https:\/\/doi.org\/10.1016\/j.jwpe.2025.108110<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46df57f9 elementor-widget elementor-widget-spacer\" data-id=\"46df57f9\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Authors: Bianca Zappulla-Sabio, Pierre Le-Clech, Ludovic F. Dum\u00e9e, Hari Kalathil Balakrishnan, H\u00e8ctor Moncl\u00fas, Ga\u00ebtan Blandin The hidden challenge of membrane recycling: how drying affects membrane layers? Improper management or storage after discharge of thin film composite membranes are challenging due to potential drying, which may affect the integrity of the material, decrease the performance and &hellip; <a href=\"https:\/\/lequia-udg.com\/ca\/2025\/07\/17\/the-hidden-challenge-of-membrane-recycling-how-drying-affects-membrane-layers\/\" class=\"more-link\" title=\"Continue reading <span class=\"screen-reader-text\">The hidden challenge of membrane recycling: how drying affects membrane layers?<\/span>&#8220;>Continue reading <span class=\"screen-reader-text\">The hidden challenge of membrane recycling: how drying affects membrane layers?<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"footnotes":""},"categories":[64],"tags":[],"class_list":["post-14543","post","type-post","status-publish","format-standard","hentry","category-articles-ca"],"_links":{"self":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14543","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/comments?post=14543"}],"version-history":[{"count":1,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14543\/revisions"}],"predecessor-version":[{"id":14544,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/posts\/14543\/revisions\/14544"}],"wp:attachment":[{"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/media?parent=14543"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/categories?post=14543"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lequia-udg.com\/ca\/wp-json\/wp\/v2\/tags?post=14543"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}